Crash testing and evaluation of F-shape barriers on slopes. Technical report Sheikh, Nauman M ; Bligh, Roger P ; Menges, Wanda L

Av: Medverkande: Utgivningsinformation: College Station, TX The Texas A&M University System. Texas Transportation Institute. Texas Department of Transportation. Research and Technology Implementation Office, 2008Beskrivning: 76 sÄmnen: Onlineresurser: Abstrakt: The TxDOT Roadway Design Manual currently suggests that concrete barrier not be placed on slopes steeper than 10H:1V. This suggestion has limited the placement of concrete barriers to narrow, flat, paved medians or at the edge of the shoulder. Based on the results of full-scale crash testing, researchers determined that TxDOT's cast-in-place permanent F-shape barrier and the precast free-standing X-bolt F-shape barrier are suitable for placement on roadside and median foreslopes of 6H:1V or less. Additionally, these barriers are suitable to be placed at any lateral offset from the roadway edge, and for any width of depressed V-ditch median as long as the barrier is placed at its center. Further, similar or better performance would be expected for barrier placement on more gentle (e.g., 8H:1V) slopes. Increasing the maximum slope on which median barriers can be placed will allow many installations to be placed further from the travelway, which in turn will most likely lead to a reduction in barrier impact frequency and severity.
Exemplartyp: Rapport, konferenser, monografier
Inga fysiska exemplar för denna post

The TxDOT Roadway Design Manual currently suggests that concrete barrier not be placed on slopes steeper than 10H:1V. This suggestion has limited the placement of concrete barriers to narrow, flat, paved medians or at the edge of the shoulder. Based on the results of full-scale crash testing, researchers determined that TxDOT's cast-in-place permanent F-shape barrier and the precast free-standing X-bolt F-shape barrier are suitable for placement on roadside and median foreslopes of 6H:1V or less. Additionally, these barriers are suitable to be placed at any lateral offset from the roadway edge, and for any width of depressed V-ditch median as long as the barrier is placed at its center. Further, similar or better performance would be expected for barrier placement on more gentle (e.g., 8H:1V) slopes. Increasing the maximum slope on which median barriers can be placed will allow many installations to be placed further from the travelway, which in turn will most likely lead to a reduction in barrier impact frequency and severity.