Welcome to the National Transport Library Catalogue

Normal view MARC view

Fiber-Reinforced Polymer Pile Repair Incorporating Cathodic Protection Aguilar, Julio ; Winters, Danny ; Sen, Rajan ; Mullins, Gray ; Stokes, Mike

By: Contributor(s): Series: Transportation Research Record: Journal of the Transportation Research Board ; 2150Publication details: Washington DC Transportation Research Board, 2010Description: s. 111-118ISBN:
  • 9780309142816
Subject(s): Bibl.nr: VTI P8167:2150Location: TRBAbstract: Fiber-reinforced polymers (FRPs) are increasingly being used for corrosion repair. As barrier elements, FRPs can only slow down corrosion. Cathodic protection (CP) is the only proven method for stopping electrochemical corrosion of steel. But a new method repairs corrosion damage: a sacrificial CP system is incorporated within an FRP repair. The system was implemented in a demonstration project in which corroding piles supporting the Friendship Trail Bridge, Tampa Bay, Florida, were repaired. The repaired piles were instrumented so that performance of the CP system could be assessed. Results indicate that the CP system is effective in protecting the reinforcing steel. It also shows that corrosion rates are lower in FRP-wrapped piles. This lower rate can increase the life of anodes used by the CP system by more than 20%.
Item type: Reports, conferences, monographs
Holdings
Current library Status
Statens väg- och transportforskningsinstitut Available

Fiber-reinforced polymers (FRPs) are increasingly being used for corrosion repair. As barrier elements, FRPs can only slow down corrosion. Cathodic protection (CP) is the only proven method for stopping electrochemical corrosion of steel. But a new method repairs corrosion damage: a sacrificial CP system is incorporated within an FRP repair. The system was implemented in a demonstration project in which corroding piles supporting the Friendship Trail Bridge, Tampa Bay, Florida, were repaired. The repaired piles were instrumented so that performance of the CP system could be assessed. Results indicate that the CP system is effective in protecting the reinforcing steel. It also shows that corrosion rates are lower in FRP-wrapped piles. This lower rate can increase the life of anodes used by the CP system by more than 20%.